Jablotron JA-121E-WH Bus Touch-Tastatur - Weiß
Jablotron JA-121E-WH Bus Touch-Tastatur - Weiß, RFID and MIFARE Frequenz.
Verfügbarkeit: Auf Lager
Artikelnummer
JA-121E-WH
Jablotron JA-121E-WH Bus Touch-Tastatur - Weiß
Touch-Tastatur bietet eine einzigartige Kombination aus modernem Design und Dual-Media-Lesetechnologie.
Die Vorderseite besteht aus speziellem, gehärtetem Kunststoff glas, das nicht leicht durch Tasten oder andere harte Gegenstände zerkratzt werden kann.
Spezifikation JA-121E-WH:
- Power supply: from control panel
- Backup (idle) power consumption: 35 mA
- Maximum power consumption: 105 mA
- RFID frequency: 125 kHz
- MIFARE frequency: 13.56 MHz
- Environment: Outdoor general
- Ingress Protection Code: IP 55
- Operational temperature range: -25 °C to +70 °C
- Dimensions: 96 x 67 x 19 mm
- Weight: 170 g
Kundenbewertungen
Produktfragen
Hi,
Would it be possible to control multiple PG outputs with JA-121E via codes in Jablotron 100? I would like to control multiple outputs (small and big gate, door) already in the system. Example input code 123456 to open PG1, 123457 PG2 and so on.
My tech who installed the system could not figure it out...
Thx for the feedback!
Nejc
Would it be possible to control multiple PG outputs with JA-121E via codes in Jablotron 100? I would like to control multiple outputs (small and big gate, door) already in the system. Example input code 123456 to open PG1, 123457 PG2 and so on.
My tech who installed the system could not figure it out...
Thx for the feedback!
Nejc
Frage von: Nejc Rajtmajer An 15.09.2023, 10:22
Hello, we have not tested it yet but you could try the following.
Please note that the JA-121E can only do PG control in this situation.
1. Select your function - probably PGon/PGoff;
2. Select the PG's you want to control;
3. Create a user (code) for each PG;
4. Make sure each user/code is authorised for a specific PG.
Regards
Please note that the JA-121E can only do PG control in this situation.
1. Select your function - probably PGon/PGoff;
2. Select the PG's you want to control;
3. Create a user (code) for each PG;
4. Make sure each user/code is authorised for a specific PG.
Regards
Antwort von: Frank Ligthart (Admin) An 16.09.2023, 12:10
Another thing:
1. Make sure you work with the latest firmware in the control panel and keypad;
2. The PG output should be on 'Pulse' reaction.
Regards
1. Make sure you work with the latest firmware in the control panel and keypad;
2. The PG output should be on 'Pulse' reaction.
Regards