Jablotron JA-121E-BK Bus Outdoor Keypad with Reader, Black
Jablotron JA-121E-BK is a black bus outdoor keypad with reader, RFID and MIFARE frequency.
Availability: In stock
SKU
JA-121E-BK
Jablotron JA-121E-BK Bus Outdoor Keypad with Reader, Black
Touch keypad offer a unique combination of modern design with dual media reading technology.
The front surface is made of special synthetic tempered glass that cannot be easily scratched by keys or other hard objects.
Specifications JA-121E-BK:
- Power supply: from control panel
- Backup (idle) power consumption: 35 mA
- Maximum power consumption: 105 mA
- RFID frequency: 125 kHz
- MIFARE frequency: 13.56 MHz
- Environment: Outdoor general
- Ingress Protection Code: IP 55
- Operational temperature range: -25 °C to +70 °C
- Dimensions: 96 x 67 x 19 mm
- Weight: 170 g
Customer Reviews
Product Questions
Hi,
Would it be possible to control multiple PG outputs with JA-121E via codes in Jablotron 100? I would like to control multiple outputs (small and big gate, door) already in the system. Example input code 123456 to open PG1, 123457 PG2 and so on.
My tech who installed the system could not figure it out...
Thx for the feedback!
Nejc
Would it be possible to control multiple PG outputs with JA-121E via codes in Jablotron 100? I would like to control multiple outputs (small and big gate, door) already in the system. Example input code 123456 to open PG1, 123457 PG2 and so on.
My tech who installed the system could not figure it out...
Thx for the feedback!
Nejc
Question by: Nejc Rajtmajer on Sep 15, 2023, 10:22 AM
Hello, we have not tested it yet but you could try the following.
Please note that the JA-121E can only do PG control in this situation.
1. Select your function - probably PGon/PGoff;
2. Select the PG's you want to control;
3. Create a user (code) for each PG;
4. Make sure each user/code is authorised for a specific PG.
Regards
Please note that the JA-121E can only do PG control in this situation.
1. Select your function - probably PGon/PGoff;
2. Select the PG's you want to control;
3. Create a user (code) for each PG;
4. Make sure each user/code is authorised for a specific PG.
Regards
Answer by: Frank Ligthart (Admin) on Sep 16, 2023, 12:10 PM
Another thing:
1. Make sure you work with the latest firmware in the control panel and keypad;
2. The PG output should be on 'Pulse' reaction.
Regards
1. Make sure you work with the latest firmware in the control panel and keypad;
2. The PG output should be on 'Pulse' reaction.
Regards
Answer by: Frank Ligthart (Admin) on Sep 18, 2023, 10:29 AM